In order to do this any over cladding must have so many anchors bolts fixings down into the beams below the cement asbestos roof sheets that there will be a considerable amount of drilling of the existing asbestos cement roof sheets.
Over cladding garage roof.
As metal sheets an over clad is highly likely to develop rust and corrode from the inside meaning ugly orange patches of rust start flaking off the edges of the roof.
The typical thickness range for sheathing is 3 8 to 3 4 inch.
It therefore requires no additional structural supports.
8d ring shank nails should be used instead.
Complete peace of mind.
Top garage roof cladding garage roof cladding welcome in order to the website in this moment we ll teach you in relation to keyword.
The first stage is to fix a framework to hold the metal sheets in place directly to the purlins underneath the asbestos cement roof sheets.
Now this is the 1st graphic.
Verges can then be created by using a ridge piece or alternatively nailing the final corrugation over a raised barge board.
Will be in which incredible.
Leaving the exiting roof material in place eliminates the need for expensive removal actions whilst the over cladding exercise will also eliminate the risks associated with asbestos exposure.
At an existing 1970s home and garage in cap cod the whole house including the garage had its dated exterior cladding removed replaced with vertical strips of kebony clear siding and a freedom gray copper standing seam metal roof.
Sheathing should be a minimum of 19 32 inch thick.
Filon over roofing is lightweight yet strong and is manufactured to the same profile as the existing roof.
This creates a risk since over cladding contractors often say you don t need to empty your garage and with all this drilling you may contaminate the contents with asbestos fibres.
Start at the opposite end to the prevailing winds again and allow overlaps of 125mm.
The garage doors were clad in the same material to help them match and their deep inset provides a deep shadow.
As the weight of the system is less than that of the potential water absorbed by the existing asbestos cement and fibre cement sheets there is no requirement for structural calculations.
Once the sheets are fixed into place you can install the ridges.
If you believe thus i l l explain to you.
This is so frequent that some contractors make a living solely fixing cut edge corrosion which can occur very quickly on a metal roof.
Roof sheathing comes in grid marked 4 by 8 foot sheets and should be installed perpendicular to the frame.
Install ridges and verges.
This course of action causes minimal disruption to business activities and also provides added insulation to the roof construction.